3/4" Flow Sensor

USS-HS43TLT Stainless Steel 3/4" Water Flow Sensor with Temperature NTC10K B3950

USS-HS43TLT stainless steel 3/4" water flow sensor with 304 stainless steel body, G3/4" connection, pulse signal output. Ideal for water heaters, water treatment equipment and various applications. Professional manufacturer: iSentrol.

USS-HS43TLT Stainless Steel 3/4" Water Flow Sensor with Temperature NTC10K B3950

Product Overview

USS-HS43TLT G3/4" (DN20) 3/4" Port with Temperature Control

High precision impeller-type electronic flow meter, suitable for measuring water or liquids with similar viscosity. Features 304 stainless steel valve body with excellent corrosion resistance and long-term stability. Integrated temperature probe for convenient temperature measurement and industrial control functions.

Technical Specifications

ModelUSS-HS43TLT-NTC10K-B3950
BrandiSentrol®
Connection SizeG3/4" (DN20) 3/4" Male Thread
Housing Material304 Stainless Steel
Impeller MaterialHigh Temperature POM, 100°C Resistance
Shaft MaterialSUS304 Stainless Steel Shaft
Applicable MediumWater or liquids with similar viscosity
Medium Temperature Range-10 ~ 100°C
Flow Range2 - 45 L/min
Accuracy±10%
Cable and WiringSM2.54 3P Red/Black/Yellow 22AWG cable, Red=VCC, Black=GND, Yellow=Signal Output; Cable Length: 35cm
SM2.54 2P Black/Black 22AWG Temperature Output; Cable Length: 35cm
Flow Signal TypePulse Signal, Square Wave
Temperature Signal TypeNTC10K B3950 Thermistor
Duty Cycle50%
Pulse CharacteristicsF(Hz) = [8 * Q] ± 10% (Horizontal Test)
Cumulative Pulse Characteristics1(L) = 480Hz ± 10% (Horizontal Test)
Maximum Pressure≤ 1.2 MPa
Operating VoltageDC 5 - 24V
Max Operating Current15 mA
Output High Level≥ (Vcc – 0.5) V
(Example: Vcc=5V → High Level ≥4.5V; Vcc=12V → ≥11.5V; Vcc=24V → ≥23.5V)
Output Low Level< 0.5 V DC
DimensionsApprox. 45mm (Length)

Specification Notes

1. The above technical specifications are for reference only. Actual performance may vary depending on operating conditions.

2. The number of pulses per liter may vary depending on the media type, viscosity, and piping installation.

3. It is recommended to calibrate the pulse coefficient in the actual installation environment for optimal metering accuracy.

Usage Tips

  • Ensure there are no rapid pulsations in the media to avoid abnormal impeller wear

  • Ensure there is no reverse pressure surge in the pipeline

  • Ensure there is no air in the system — air bubbles affect metering accuracy

  • Design the piping layout properly to minimize pressure loss

  • Pay attention to the flow meter installation position; it is recommended to install it after a straight pipe section

  • Actual flow rate should be within the linear measurement range of 2–45 L/min

  • Clean the piping system regularly to prevent debris from clogging the impeller

  • Avoid current spikes that may damage the sensor

  • Ensure correct wiring of the power positive, signal, and ground lines — incorrect wiring will damage the flow meter

  • Do not apply mechanical loads to the electrical contacts

  • Prevent the electrical contacts from getting damp; ensure connections are properly sealed

  • Route signal cables away from high-current loads to avoid electromagnetic interference (EMI)

Precautions

  • A filter screen must be installed at the water inlet to prevent particles and debris from entering and damaging the impeller.

  • The product should be installed indoors or inside equipment. Do not expose it to outdoor, humid, or high-temperature environments for extended periods. Avoid installing in locations subject to vibration or shaking, as this may affect measurement accuracy.

  • Magnetic materials or devices generating magnetic fields placed near the product may affect the sensor's output characteristics.

  • Do not disassemble the product without authorization. Disassembly may cause seal failure or calibration loss, and such products are not covered by warranty.

  • When using this turbine-type sensor to replace other models for the first time, please verify the compatibility of port dimensions and signal parameters.

  • Do not blow high-speed airflow into the product, as this may cause internal impeller damage or jamming, resulting in inaccurate flow readings or no output.

  • We reserve the right to update and improve the product for continued quality enhancement.

Applications

Residential & Commercial Water Heating: Gas water heaters, electric water heaters, tankless water heaters, wall-hung boilers, solar water heaters, heat pump water heating systems

Smart Home & Bathroom: Washing machines, dishwashers, smart bathroom fixtures

Drinking & Water Purification: Water purifiers, water dispensers, hot water boilers, water vending machines, self-service vending machines

Water Meters & Metering Systems: IC card water meters, smart water meters, hot water meters, integrated water controllers, water control machines

Smart Campus & Public Management: All-in-one card management systems, campus card water vending systems, bathroom water control systems

Industrial & HVAC Systems: Industrial cooling systems, recirculating water systems, boiler systems, central air conditioning, refrigeration equipment

Water Treatment & Agriculture: Water treatment equipment, dosing & distribution systems, agricultural irrigation systems

Professional Equipment & Instruments: Chemical metering equipment, pharmaceutical equipment, food & beverage processing equipment, medical equipment, car wash equipment, pool circulation systems, intelligent machinery, instrumentation

Company Images

OFZAT-01 Wiring Diagram
Shandong Isentrol Electronics Technology Co., Ltd. Factory